Must have done something really STUPID...
Followed a post to only use LAN-settings for communication to/from my flukso-device.
I have some aberrant network settings, so i had to do some adjusting...
Now ---> i no longer have WLAN, which is OK (that's what i wanted).
Which is not so OK i can no longer access
1) the web-interface via LAN
2) i can no longer ssh to the device by LAN
In my LAN-overview in my router, i can see the flukso with an IP-address 192.168.xxx.20
In the dash on your website i can see the figures it's sending (so that's OK for the moment)
I pushed for an upgrade, but it seems you don't see "a heartbeat".
How can i regain access?
Thank you for your help...
Hi Stefaan,
I did a quick check of the status of your FLM. The upgrade to r215 was successful. The FLM is sending heartbeats and data to the server. All seems to be fine. Are you still not able to ssh into the FLM?
Cheers,
-Bart.
Thanks for your reply Bart,
I can't SSH to my fluksometer: immediate port 22: connection refused
However i also see in my LAN a device L-TEC-1103, which i don't know at another IP-address.
When i ssh this device, i get an operation timed out?
However i can see the graphs created on flukso.net, so the system is working.
I would however be glad to regain "control".
Cheers,
Stefaan
Are you still having trouble ssh'ing to your FLM? I can't seem to find anything that would prevent you from doing so.
Cheers,
-Bart.
UPDATE: Your FLM's WAN zone firewall setting did have its input set to REJECT. Since you're using the FLM in eth mode, this would have effectively prevented you from ssh'ing into the FLM.
Thank you Bart,
I have my access back :-))
Problem solved