Problems using the RESTful api

Hi,
I'm trying to get access my data directly on the flukso server through the RESTful api.
I use the manual and replace the X-token and sensor-token by my own tokens. I get the following message (tokens modified).

roel@Enif:~$ curl -k -v -X GET -H "Accept: application/json" -H "X-Version: 1.0" -H "X-Token: dd9aa4835a7a4e0965f51c227bb1****" "https://api.flukso.net/sensor/399e12b79d5f9bf90491af155ca8****interval=month&unit=watt"

* About to connect() to api.flukso.net port 443 (#0)
* Trying 178.79.177.6...
* connected
* Connected to api.flukso.net (178.79.177.6) port 443 (#0)
* successfully set certificate verify locations:
* CAfile: none
CApath: /etc/ssl/certs
* SSLv3, TLS handshake, Client hello (1):
* SSLv3, TLS handshake, Server hello (2):
* SSLv3, TLS handshake, CERT (11):
* SSLv3, TLS handshake, Server finished (14):
* SSLv3, TLS handshake, Client key exchange (16):
* SSLv3, TLS change cipher, Client hello (1):
* SSLv3, TLS handshake, Finished (20):
* SSLv3, TLS change cipher, Client hello (1):
* SSLv3, TLS handshake, Finished (20):
* SSL connection using RC4-SHA
* Server certificate:
* subject: C=BE; O=Flukso; CN=api.flukso.net; emailAddress=admin@flukso.net
* start date: 2012-05
* expire date: 2014-05
* common name: api.flukso.net (matched)
* issuer: C=BE; O
* SSL certificate verify result: unable to get local issuer certificate (20), continuing anyway.
> GET /sensor/399e12b79d5f9bf90491af155ca8****interval=month&unit=watt HTTP/1.1
> User-Agent: curl/7.27.0
> Host: api.flukso.net
> Accept: application/json
> X-Version: 1.0
> X-Token: dd9aa4835a7a4e0965f51c227bb1****
>
* additional stuff not fine transfer.c:1037: 0 0
* HTTP 1.1 or later with persistent connection, pipelining supported
< HTTP/1.1 400 Bad Request
< Server: nginx/1.0.10
< Date: Sat, 15 Dec 2012 21:30:34 GMT
< Connection: keep-alive
< Content-Length: 0
<
* Connection #0 to host api.flukso.net left intact
* Closing connection #0
* SSLv3, TLS alert, Client hello (1):

Any idea what's going wrong?
Thanks,
roel

Are there other Brazilian Fluksonians?

Hi Guys,

Are there other Brazilians out there using FLM?

I am comparing my FLM charts against Bart´s chart but I would like to compare against others people in my region (who shall have similar home appliances, cooling system and weather conditions).

Best regards,
Benito

gas probe for meter dresser NPL12

hello,
I have a Dresser gas meter of type NPL12.

The data sheet of this meter can be found here

There is on this meter a connection for remote reading with LF pulse emitter.
Is there any chance of being able to use the gas probe with it? Any alternative solution?

Thanks for your help.

herve

Multiple clamps on one flukso port

Hi, the wiring in my fuse box is pretty complicated... In order to measure everything, I need to use two clamps (I already have one of 100A installed and planning to add another 50A clamp on a second bunch of wires). Is it possible to connect both clamps onto 1 Flukso port?
PS: My installation only has 1 phase

Tx!
J.

how consumption and solar from flukso to PVoutput

this is my installation from my working flukso:
port 1: my current consumption(flukso 50A clamp)
port 2: nothing
port 3: nothing
port 4: gas sensor(puls)
port 5: solar(puls from S0-output on kWhmeter)

Everything is working fine on Flukso.net but on PVoutput I get n't fixed, I see only my consumption and no solar....
I think I need to change the settings but I try almost everything but it dousn't work...

Can someone post me the settings for my situation please ?