Installation

Questions about installing and configuring a Fluksometer.

MODBUS over RS485

Probably a big ask but just wondering whether anyone has implemented the MODBUS protocol on the RS485 inputs? I have a Schneider Electric Conext RL inverter.

I have details on the Conext MODBUS protocol but as I'm new to the Flukso would appreciate any tips on how to implement this protocol. Is there something similar someone could point me to?

Many thanks!

S0 pulse meter - pulse length 30ms supported?

Hi everyone,

I'm new here, so a short introduction might be welcome. I'm from Austria, live near Vienna and am passionate about collecting and graphing all kinds of data I can get my hands on.

I am about to order a flukso v2b and would be happy if someone could answer me a few questions beforehand.

I plan a setup like this:
- main: 3 phase S0 pulse meter for total electricity consumption metering
- detail: up to 4 selected points for detailed measurement of parts of my house using a combination of clamps and single-phase S0 meters

Question 1: That should work like I imagine, right?

Question 2: Is there a difference in the results between using an S0 meter and a clamp?

Question 3: The B+G E-Tech DRT428DC-V3 S0 meter seems an inexpensive product to me and has 2000imp/kWh with a pulse length of 30ms.
I have already read the posts regarding the imps/kWh and think the 2000 should work fine (I like it being more granular than a 1000imp/kWh one).
But what about the pulse length, I haven't found any info on that. Is 30ms a supported value, or to I need a 90ms meter?

Thank you four your feedback!
Florian

flukso to run 5 pulse ports?

is the flukso able to run 5 pulse ports or is it only 1 analog and 4 pulse the maximum it can handle?

Pulse Water meters

looking for some sort of pulse unit to measure water.

found these water meters but the one that does 1 pulse/0.5L only is 25mm im looking for a 40mm
http://www.fluidflo.com.au/25mm-brass-coup-p-1100.html

the 40mm i have found does 1 pulse/10L
http://www.fluidflo.com.au/multijet-cold-water-c-910_1494.html

does anyone know of any decent 1 pulse per 0.5-5L units? they dont have to be actual water meters just that thats all i seem to be able to find.
looking for 40mm size as to not restrict pipework and allow a decent flow through

Pulse output 100imp/kWh

I am looking at ordering a DIN mounted single phase kW/h meter with a pulse output of 100 imp/kWh. Can someone confirm that this would be compatible with the Flukso and that I would set the meter constant to 10?