6 smart-main sensors on Fluksometer v2b

During the installation i've had some issue's with my Fluksometer v2b, resultsing in 3 electricity smart-main sensors and 3 gas smart-main sensors. Looks like the device works fine now, but how could the not used sensors be removed?

Incorrect Watts

On a new install I seem to have a reading of 25w when no power is being generated.

The inverter has its own watt meter and it reads 1w. I also hooked up a watt meter to the power cord and it's reading 3.3w.

Is there some way of adjusting the readout or calibration for the sensor. or do I have to try another sensor or input?

Thanks
Kym

Watermeter: connected sensor delivered by Flukso generates strange graphics

Hi,
2 years ago I installed Flukso V2 to measure 3 phase 400V accumulator heating at night + solar panel production during the day. Lucky for me Flukso doesn't make no difference between incoming or outgoing electricity. I can use the same graph for both measures. Anyway, because of issues with water supply I ordered a small Flukso sensor (+ 2 meter cable) compatible with a Kent V100 grenade watermeter.
Flukso wifi Port 1 2 3 : each phase of 400V accumulator heating + solar production on P2 P3
Pulse 4: free (was solar pulse)
Pulse 5: watermeter pulse
74f6a782307e5fcc92cf370f15dd3925 9725a3b1b77dacc0b8bbc97026c30579 electricity ph3
c955c7c23d98c60874c726548d57b36b f9280fff7bef2ee1563caef583783639 water free
80b2a9d3345fa270076fa389fc493ee8 ae5f5a062db94b9cbdc9caa905c72217 water water2
As a parameter I used a value of 10
In short 22 meter wire (2) connects pulse port and sensor.
I put the sensor into a small hole just under the analog meter type Kent v100 Grenade (XXXX,YYYYZ).
Now I get readings between 300 and 4,000 litres/day which is not possible. I also get the same value for hours and suddenly the value drops to 1/10 and stays there for another couple of hours.
I thought the readings should follow water consumption but strangely it just provide the same value for hours and than it jumps to another value. Only the day graphic shows the figures.
Has anybody similar experience with watermetering? Is the graph incorrect? Is the sensor faulty?
Any advice welcome.
Marc Verbeke, Belgium (OVL)

New install. No graph

Just installed a new FLM. The electricity sensor is apearing on the sensor page with the correct name.
Nothing shows on the graph page? Could this be caused by the fact that its night time and theres no stored data for this meter recently and current output is 0w.

I saw another post here where someone had the same issue and it seems replacement of the FLM was the solution.
I'd rather not take this road if possible, but perhaps a factory reset would help as the unit is second hand.

Thanks
Kym

3 phase pulse counter

im looking for a decent 3 phase pulse counter so i can meter my 3 phase power with a pulse port on a fluxo. must be certified for australia.

also any decent pulse counters for water pipes i will want 3.
2 pipes will be 1" or 1.5" and one probably 2"