Installation

Questions about installing and configuring a Fluksometer.

Setup Flukso

i currently have a Current Cost ENVIR unit but looking to measure water.

if i buy a Flukso to replace my CC ENVIR can i export my data directly to PVoutput.org?

does the Flukso require a computer to handle export of the data or does it handle it itself?

is flukso capable of exporting data in 5 min intervals ?

i read in the forums that the water usage isnt live.. is this able to be worked out in 5 min intervals aswell?

Can i extend the Water probe cables 6-8m? as my water meter is about that far from my meterbox and the cable is only 2m long

if the power or wifi goes down is the unit capable of holding the data until its able to be uploaded? and for how long?

Maximum length analog clamp wire

Hi

I found a lot about the maximum length for the pulse wires, but nothing about the analog clamps.
Any idea how long they can be?

Yves

Flukso upgrade options removed from shop

Hello,

I would like to upgrade my FLM02A to the new B version, I noticed the upgrade option in the shop has disappeared? Is this an error?

What options are there to upgrade to the B version? I would really like to have more than 2 pulse counters.

Data being posted but no graphs

Hi
I hope some one can help me, I have installed a FLM about six weeks ago and have not been able to see any graphs on the Flukso Dash, the only one that works is the minute one which tells me that the sensors are working fine. the FLM has the heartbeat and globe light light and I can see in the sys log data is being posted, also when I log in to the Flukso web into my account I can see the sensors and the latest heartbeats being received. Is there a problem with the Flukso servers? or have I purchased a faulty unit.
Any help appreciated.

no reading from P1 kamstrup

Hi,

this day i received the flukso box. Looking pretty good!

Its configured on my local network on ip 192.168.0.142 and my mac is on 192.168.2.100. All working fine, meaning I can connect to the webinterface.

I hooked it up to the P1 port on my dumb kamstrup meter, but I am not getting a signal. Isee posts in the syslog like POST https://api.flukso.net/device/40e73c4b:200 but i dont have the feeling it is recording something.

What I am unsure of is that the sensor page only shows 5 sensors, but the P1 hangs on port 6... so maybe it is still disabled, but on flukso.net i see prefilled 2 smart-main sensors, so i guess these i need, so asking the api for http://192.168.0.142:8080/sensor/2dc07068223f32292bcf960cdd9b23ce?versio... should return some readings isn't it ? anyway it returns something, but it is an empty array.

I must admit that i reset the box twice (>10<20 secs) and i ran fp1 once from terminal.

can you help me out ?

rgds

Pieter

here is some more info
root@flukso-4xxx:/www/sensor# /etc/init.d/flukso restart
Daemon returned 0 as return value.
Daemon returned 0 as return value.
Daemon returned 0 as return value.
Daemon returned 0 as return value.
Daemon returned 0 as return value.
Daemon returned 0 as return value.
root@flukso-4xxx:/www/sensor# /etc/init.d/flukso stop
root@flukso-4xxx:/www/sensor# cat /dev/ttyS0
????????????????????????

and syslog complains about empty telegrams