Installation

Questions about installing and configuring a Fluksometer.

sensor configuration does not update on flukso.net

Hi there,

after updating my Flukso FL03001327 from firmware 232 to 247 sensor config changes do not show up on the flukso.net dash.
I formerly had configured input one as 3phase input and changed to 3 onephase inputs after firmware update.
While status in the Flukso device menu reflects the changes properly flukso.net still shows the old sensor configuration under "sensors" in configuration menu and does not display data in the graph for the second and third input.
Please help!

Regards
TCHW

Flukso and hot weather (38 degrees celsius plus)

Hi Flukso team

I have had a Flusko running nicely for months now. Today has been an unseasonabley hot day in Sydney, and my Flusko has stopped operating properly - it's just showing 2, 3 or 4W usage, even though all the lights are on. This happened when the thermometer reached 38.8 C. It's now 32.5 C and it still hasn't started reporting 'reasonable' numbers.

I haven't power cycled the device yet, but can do if recommended.

This raises a question - what is the operating temperature of the Flukso?
Thanks for any advice.

Does the water probe support this kind of meter?

Hello,

instead of the grenade type of water meter I have this water meter at home (Belgium):
https://goo.gl/photos/nYAkw6sG5oRW5nzo7
I was wondering if it would be possible to measure anything with this kind of meter.
I would like to know before I also order a water probe because it's not much use to buy one if I can't do any measurement.
Was also wondering are there alternatives for installing my own water meter in the circuit that actually gives a pulsed output (which don't cost an arm and a leg), I am a tinkerer who is not afraid of adapting my water installation if I have to ...

kamstrup data on chart not enough updates

Hi,

About 9 months ago I bought the fluxo and attached it to my kamstrup dump meter.

Icarus made some config changes as I did not get nice data on /dev/ttyS0. After that I got data of my electricity, gas and water. But I never ever saw it appearing in the dash chart.

This day I upgraded my box, and wow I see data in the chart, But I only see updates per approximately 40 minutes.

dev/ttyS0 gives this and port 1-0:1.7.0 gives each 10 secs a nice different value.
To me it looks like 1-0:1.8.1 port is read instead of 1-0:1.7.0

Can you please help me out ?

here is my /dev/ttyS0
0-0:96.1.1(205A414246303031353533343231303131)
1-0:1.8.1(12593.000*kWh)
1-0:1.8.2(12151.000*kWh)
1-0:2.8.1(00000.000*kWh)
1-0:2.8.2(00000.000*kWh)
0-0:96.14.0(0001)
1-0:1.7.0(0000.90*kW)
1-0:2.7.0(0000.00*kW)
0-0:17.0.0(999*A)
0-0:96.3.10(1)
0-0:96.13.1()
0-0:96.13.0()
0-1:24.1.0(3)
0-1:96.1.0(3338303034303031313038323739333131)
0-1:24.3.0(150920200000)(08)(60)(1)(0-1:24.2.1)(m3)
(13252.136)
0-1:24.4.0(1)
!
/KMP5 ZABF001553421011

only seeing 1 current clamp out of 3

I have 3 fases + N coming in, all these three have a 50 amp analog current clamp installed.

In the chart in dash I only see the first fase. I configured the sensors as 3 current clamp ports and tried number of fases setting 1 and enable all three sensors, hoping to see three charts. But I only see the first one (polarity of clamps is fine, )

Also I tried number of fases set to three, but then i cant enable port two and three, anyway i keep on seeing only the first attached clamp

- whats the correct setting to use ?
- is there any way to check the values directly like i can on dev/ttyS0 for my kamstrup ?

I tried fetching data from sensor 2 and 3 via http://192.168.0.131:8080/sensor/e799eef472075263e184cefc3b51d202?versio... But these array are empty ...

Please help me out