Get Power Used from smart-meter on main fuse & PV

Hi all,

I have a Flukso V2 where I hooked two smart meters using pulse signals:

1) "main" meter located on the main fuse box (between grid cable and household fuses). http://www.top-messtechnik.com/jtlshop/index.php?a=476&lang=eng
2) "PV" meter located right after my inverter, that is injecting power into a second fuse box (in my kitchen)

I'm not an expert in electricity so I'll try to draw a schema of the setup:

GRID ---- "main" meter ---- Main fusebox ---- Secondary fusebox ---- "PV meter" ---- Inverter

The PV injection into the secondary fusebox can't be changed.

Before installing PV, the "main" meter was used to monitor household consumption. However, since the PV is installed and generating power, the signal of the "main" meter that is pushed to the Flukso seems to take into account generation (PV) and househould consumption. This results in a signal that is equal to the household consumption when no power is injected (see red line in figure below, before 10:30 AM and after 6:30PM). When power is injected, the main signal follows the PV (blue line) and the difference between the blue and red seems to be equal to the net consumption (import/export from/to the grid).

See: https://d2r1vs3d9006ap.cloudfront.net/s3_images/1498950/RackMultipart201...

Does this make sense?

I wanted then to push the data to pvoutputs and given assumptions above, I have setup the auto upload from the Flukso device like this:
https://d2r1vs3d9006ap.cloudfront.net/s3_images/1498951/RackMultipart201...

In the first device, I subtract the Generated power ("PV" Meter) from the Power recorded at "Main" Meter. This is, according to me, returning the Net Consumption and not the Power used.

In the second device, I get the "PV" meter data only which I'm sure is Generated Power only.

The result on pvoutput is this:
https://d2r1vs3d9006ap.cloudfront.net/s3_images/1498952/RackMultipart201...

The Power Used seems therefore to show the Net Consumption and not the actual power used (without pv contribution). Therefore I'm not sure that the Net Energy (import or export) figures are correct.

My question: Is it possible to setup the automatic upload in order to get the Power Used instead of Net Consumption in my situation? Does someone can help me to set it up on pvoutputs?

I asked some help from their forum and someone suggested to replace my current configuration by:

Primary device
- Direction = Solar
- Sensor = PV Meter

Secondary device
- Direction = Net
- Sensor = Main Meter

This now yields this:
https://d2r1vs3d9006ap.cloudfront.net/s3_images/1499504/RackMultipart201...

There is still something I don't really get: in the graph above, we can see that the Power used follows directly the PV generation. Therefore there is a peak in the consumption directly linked with the peak of production. My consumption is therefore way too high as it seems to take into account the PV generation.

I tried several setups but can't get it right... So I just would like some help from you guys, and hopefully be able to extract the power consumption given my electrical setup.

Thanks a lot,
Greg

get separated readings from the 3 phases

I have 3 phases and 3 sensors for electricity. Each sensor is configured separated however on the Dash I only get a single reading I don’t know if it comes from the 3 sensors added or a single one and the others are ignored. I would like to have the 3 readings separated but I don’t know how to configure the unit. Can I have your help?

using flukso sensor/token for export to another site

does anyone know how the flukso outputs the data for pulse output for water?

i have pvoutput using the flukso sensor and token to collect the water usage.
it works fine for electricity but with water it doesn't work properly. either shows too little or doesn't show at all

Purchasing a Flukso

A few people I know want (or did want ) a Flukso. They are not on sale due to the "new" one coming?
Sales are going to other equipment suppliers. Why cant the V2 model still be obtained?
I promote the unit on forums etc but not much point anymore.
People wont wait :(

No P1 data after smartmeter switch

After a smartmeter switch initiated by the energy infrastructure company there is no data coming through over the P1 connection on my FLM2b, and no data is sent to pvout. I have switched to DSMR 4 and back to 2.2 to no avail. Last part of syslog attached below, device is on firmware 250
I have no clue what is going on or what I can do to get it working again. Any help is greatly appreciated.

Jaap

Jan 1 00:01:06 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:06 flukso-297d47 daemon.info supd[680]: Sucessfully started with DEAMON=supd and DAEMON_PATH=/var/run/supd
Jan 1 00:01:07 flukso-297d47 daemon.info spid[683]: Sucessfully started with DEAMON=spid and DAEMON_PATH=/var/run/spid
Jan 1 00:01:07 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:07 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:07 flukso-297d47 daemon.info fluksod[686]: Sucessfully started with DEAMON=fluksod and DAEMON_PATH=/var/run/fluksod
Jan 1 00:01:08 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:08 flukso-297d47 daemon.info tmpod[689]: Sucessfully started with DEAMON=tmpod and DAEMON_PATH=/var/run/tmpod
Jan 1 00:01:09 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:09 flukso-297d47 daemon.info parsed[695]: Sucessfully started with DEAMON=parsed and DAEMON_PATH=/var/run/parsed
Jan 1 00:01:10 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:10 flukso-297d47 daemon.info kubed[698]: Sucessfully started with DEAMON=kubed and DAEMON_PATH=/var/run/kubed
Jan 1 00:01:19 flukso-297d47 user.info heartbeat[701]: POST https://api.flukso.net/device/297d47846b1c53d0d14010173d7c9895: 200
Jan 1 00:01:21 flukso-297d47 daemon.info supd[680]: Received event START for ntp
Sep 14 17:15:30 flukso-297d47 cron.err crond[576]: time disparity of 24564554 minutes detected
Sep 14 17:30:01 flukso-297d47 cron.info crond[576]: crond: USER root pid 774 cmd /usr/bin/fcheck
Sep 14 17:45:02 flukso-297d47 cron.info crond[576]: crond: USER root pid 819 cmd /usr/bin/fcheck
Sep 14 18:00:01 flukso-297d47 cron.info crond[576]: crond: USER root pid 864 cmd /usr/bin/fcheck
Sep 14 18:01:01 flukso-297d47 cron.info crond[576]: crond: USER root pid 885 cmd /usr/bin/heartbeat 0
Sep 14 18:01:03 flukso-297d47 user.info heartbeat[886]: POST https://api.flukso.net/device/297d47846b1c53d0d14010173d7c9895: 200
Sep 14 18:14:05 flukso-297d47 daemon.notice netifd: wan (468): Sending renew...
Sep 14 18:14:05 flukso-297d47 daemon.notice netifd: wan (468): Lease of xxx.xxx.xxx.xxx obtained, lease time 7200
Sep 14 18:15:01 flukso-297d47 cron.info crond[576]: crond: USER root pid 950 cmd /usr/bin/fcheck