Installation

Questions about installing and configuring a Fluksometer.

Purchasing a Flukso

A few people I know want (or did want ) a Flukso. They are not on sale due to the "new" one coming?
Sales are going to other equipment suppliers. Why cant the V2 model still be obtained?
I promote the unit on forums etc but not much point anymore.
People wont wait :(

No P1 data after smartmeter switch

After a smartmeter switch initiated by the energy infrastructure company there is no data coming through over the P1 connection on my FLM2b, and no data is sent to pvout. I have switched to DSMR 4 and back to 2.2 to no avail. Last part of syslog attached below, device is on firmware 250
I have no clue what is going on or what I can do to get it working again. Any help is greatly appreciated.

Jaap

Jan 1 00:01:06 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:06 flukso-297d47 daemon.info supd[680]: Sucessfully started with DEAMON=supd and DAEMON_PATH=/var/run/supd
Jan 1 00:01:07 flukso-297d47 daemon.info spid[683]: Sucessfully started with DEAMON=spid and DAEMON_PATH=/var/run/spid
Jan 1 00:01:07 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:07 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:07 flukso-297d47 daemon.info fluksod[686]: Sucessfully started with DEAMON=fluksod and DAEMON_PATH=/var/run/fluksod
Jan 1 00:01:08 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:08 flukso-297d47 daemon.info tmpod[689]: Sucessfully started with DEAMON=tmpod and DAEMON_PATH=/var/run/tmpod
Jan 1 00:01:09 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:09 flukso-297d47 daemon.info parsed[695]: Sucessfully started with DEAMON=parsed and DAEMON_PATH=/var/run/parsed
Jan 1 00:01:10 flukso-297d47 user.info sysinit: Daemon returned 0 as return value.
Jan 1 00:01:10 flukso-297d47 daemon.info kubed[698]: Sucessfully started with DEAMON=kubed and DAEMON_PATH=/var/run/kubed
Jan 1 00:01:19 flukso-297d47 user.info heartbeat[701]: POST https://api.flukso.net/device/297d47846b1c53d0d14010173d7c9895: 200
Jan 1 00:01:21 flukso-297d47 daemon.info supd[680]: Received event START for ntp
Sep 14 17:15:30 flukso-297d47 cron.err crond[576]: time disparity of 24564554 minutes detected
Sep 14 17:30:01 flukso-297d47 cron.info crond[576]: crond: USER root pid 774 cmd /usr/bin/fcheck
Sep 14 17:45:02 flukso-297d47 cron.info crond[576]: crond: USER root pid 819 cmd /usr/bin/fcheck
Sep 14 18:00:01 flukso-297d47 cron.info crond[576]: crond: USER root pid 864 cmd /usr/bin/fcheck
Sep 14 18:01:01 flukso-297d47 cron.info crond[576]: crond: USER root pid 885 cmd /usr/bin/heartbeat 0
Sep 14 18:01:03 flukso-297d47 user.info heartbeat[886]: POST https://api.flukso.net/device/297d47846b1c53d0d14010173d7c9895: 200
Sep 14 18:14:05 flukso-297d47 daemon.notice netifd: wan (468): Sending renew...
Sep 14 18:14:05 flukso-297d47 daemon.notice netifd: wan (468): Lease of xxx.xxx.xxx.xxx obtained, lease time 7200
Sep 14 18:15:01 flukso-297d47 cron.info crond[576]: crond: USER root pid 950 cmd /usr/bin/fcheck

Three phase Consumption and Three phase Generation

Howdy

I've got a 3 phase building that we've just had 3 phase solar installed onto. The inverter doesn't support PVoutput (only via CSV) and I would love to be a part of that so I'm looking at Flukso coming to the rescue.

I would like to measure both our buildings consumption as well as the solars generation.

Would I be best off using TWO fluksometers (6 clamps in total)? If so how would that work as an input to PVoutput? Would I end up with 6 graph lines?

Thank you

Sensor locks up entire device after version 250 upgrade

Sensor locks up entire device after version 250 upgrade

Any suggestion how to stop port 1 from sampling the port every 1 sec ?

1471372776: /sensor/1f6becfdb09d37704db0174c683e59d8/gauge ~> [1471372775,218,"W"]
1471372776: /sensor/2280a579f5bbaa26a6e83feadf9b5c36/gauge ~> [1471372775,0,"L/day"]
1471372776: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372774,0,"W"]
1471372776: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372773,0,"W"]
1471372773: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372772,0,"W"]
1471372773: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372771,0,"W"]
1471372773: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372770,0,"W"]
1471372770: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372769,0,"W"]
1471372770: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372768,0,"W"]
1471372770: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372767,0,"W"]
1471372767: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372766,0,"W"]
1471372767: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372765,0,"W"]
1471372767: /sensor/1f6becfdb09d37704db0174c683e59d8/gauge ~> [1471372765,215,"W"]
1471372767: /sensor/1f6becfdb09d37704db0174c683e59d8/counter ~> [1471372765,-862546,"Wh"]
1471372767: /sensor/2280a579f5bbaa26a6e83feadf9b5c36/gauge ~> [1471372765,0,"L/day"]
1471372767: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372764,0,"W"]
1471372764: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372763,0,"W"]
1471372764: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372762,0,"W"]
1471372764: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372761,0,"W"]
1471372761: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372760,0,"W"]
1471372761: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372759,0,"W"]
1471372761: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372758,0,"W"]
1471372758: /sensor/2280a579f5bbaa26a6e83feadf9b5c36/counter ~> [1471370604,3346109,"L"]
1471372758: /sensor/1f6becfdb09d37704db0174c683e59d8/counter ~> [1471372745,-862547,"Wh"]
1471372758: /sensor/2280a579f5bbaa26a6e83feadf9b5c36/gauge ~> [1471372755,0,"L/day"]
1471372758: /sensor/1f6becfdb09d37704db0174c683e59d8/gauge ~> [1471372755,190,"W"]
1471372758: /sensor/bba73e3897b44963dd7ffce2b1cfde7e/gauge ~> [1471372757,0,"W"]

water meter

Some time ago I bought the water reed switch sensor. I have never been able to use it because I am in the US and here water meters do not use reed switches for the most part... When they finally put one in on my area that had a reed switch they cut off my cable and I got in lots of trouble for putting a "cable" on their equipment... never again.

So I am giving this another round... Searching the net I found this water meter and has a pulse output:
https://assuredautomation.com/literature/IM/AA_User_Manual_WM-PC.pdf

They have an option to come with the reed switch installed.
https://assuredautomation.com/WM-PC/index.php

Would this work with flukso v2?

I plan to install it right at the main line of my sprinkler system.

TIA.

Regards,
-